U-CROWN Super DC Inverter Ecodesign - Technical Specifications

 

Model GRS 101 EI/JSC2-N2 GRS 121 EI/JSC2-N2 GRS 181 EI/JSC2-N2
Factory Model GWH09UB-K3DNA4F GWH12UB-K3DNA4F GWH18UC-K3DNA4F
Capacity kW 2,60 3,00 3,50 3,60 5,28 5,28
Capacity Btu/h 8.871 10.236 11.942 12.283 17.998 17.998
Pdesign (C/A/W)* kW 2,60 2,70/2,70/2,80 3,50 3,00/3,00/3,20 5,20 6,20/5,20/5,30
Capacity Range kW 0,39-4,00 0,56-4,80 0,39-4,45 0,56-5,40 0,90-5,75 0,75-7,25
Capacity Range Btu/h 1.331-13.648 1.911-16.378 1.331-15.183 1.911-18.425 3.071-19.619 2.559-24.737
Power Input (min-nom-max) W 95-600-1.500 100-800-1.630 95-920-1.550 100-970-1.680 200-1.600-2.050 200-1.420-2.400
Current Input (nom) A 2,7 3,5 4,10 4,20 7,10 6,20
Annual Consumption kWh/ann 121 1.492/822/769 175 1.658/913/878 298 4.200/1.820/1.855
SEER - SCOP(C/A/W) - Class W/W 7.50 A++ 3,8A/4,60A++/5,10A+++ 7,00 A++ 3,80A/4,60A++/5,10A+++ 6,10 Α++ 3,10B/4,00A+/4,00A+
Ambient Temperature Range oC -18~54 -30~24 -18~54 -30~24 -18~54 -30~24
Power Supply V-Ph-Hz 230V ~ 1N - 50 Hz 230V ~ 1N - 50 Hz 230V ~ 1N - 50 Hz
Power Connection Cable ODU.-IDU. / Com. mm2 3×1,5 - OXI / 4×1,5 3×1,5 - OXI / 4×1,5 3×2,5 - OXI / 4×1,5
Air Flow Volume m3/h 650/530/470/400/350/300/290 720/550/490/420/370/320/290 850/750/650/600/500/400/340
Sound Pressure Level IDU (H/M/L) - ODU. dB(A) 41/37/35/33/30/22/19 - 50 43/38/36/34/31/23/20 - 52 46/42/40/36/33/25/22 - 56
Sound Power IDU (H/M/L) - ODU dB(A) 56/50/48/46/43/35/32 - 59 57/51/49/47/44/36/33 - 60 58/54/52/48/45/37/34 - 62
Diameter Liquid-Gas Connection Pipe inch 1/4″ - 1/2″ 1/4″ - 1/2″ 1/4″ - 1/2″
Refrigerant charge (precharge/after 5m) R410 - 1,30kg
/ 20g/m
R410 - 1,30kg
/ 20g/m
R410 - 1,65kg
/ 20g/m
Max Distance /Height Connection Pipe m 15 / 10 20 / 10 25 / 10
Indoor Unit Dimension LxHxD/ Weight mm/kg 860x305x170 / 11,5 860x305x170 / 11,5 960x320x205 / 14
Outdoor Unit Dimension LxHxD/ Weight mm/kg 899x596x378 / 44,5 899x596x378 / 44,5 950x700x396 / 51

*Colder, Average, Warmer climate zones for heating operation